PROJECT PLANNING
4
15
8017621/ZPQ5/2017-08-15|SICK
Subject to change without notice
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | AOS502 STS
4.1.2
Input and output signals
All input and output signals from the laser scanners are directly connected to the
Flexi Soft control.
The
Out 1
to
Out 5
LMS outputs signal the status of the assigned monitoring field to the
respective inputs of the Flexi Soft control.
The Flexi Soft control analyzes the status signals from the laser scanners based on the
stored monitoring scenarios and transmits corresponding
stop
and
warning signals
to
the higher-level crane control.
Fig. 5: Interaction between the input and output signals
LMS output
Out 6
is used to signal the contamination of the laser scanner to the Flexi Soft
control. If contamination is low, a warning is displayed; if contamination is high, an error is
displayed.