CLV 41x Bar Code Scanner
Ø
Procedure for teaching in match code 1
Prerequisite:
CLV is in Reading mode and the current parameter set (if
application-specific) is stored permanently.
Notes:
1. In order to replace the match code taught in in this way with a different match
code, you can repeat steps 3 to 6 without having to switch off the CLV.
2. If match code 1 is set using the teach-in method, it must not be modified with the
user interface (or command strings) until the CLV is switched off again. The
methods used to set the match code cannot be mixed. This does not affect
match code 2.
Result 1 to Result 3 switching outputs
The three outputs (
Fig. 7
) can each be assigned different result functions. When the
associated result occurs, the corresponding output becomes live for the selected
pulse duration at the end of the reading interval. The pulse duration can be set
separately for each output.
Step
Action
Response from CLV
1)
1
Switch off CLV
–
2
Close switch S and
CLV switches to Reading mode and activates
switch on CLV again
teach-in mode for the match code.
3
Open switch S
CLV in teach-in mode and searches match
code.
4Position match code at appropriate –
distance (
see 16. Reading field
diagrams
)
5
Trigger set reading pulse
CLV reads the match code.
The Result LED lights up to confirm
successful read (good read; default setting).
Beeper emits a short acoustic signal.
6
Close switch S again
CLV stores the match code and its code type
in the valid parameter set and permanently
in the EEPROM.
From this point on, it compares each match
code read with the match code taught in.
1) We recommend that you connect the PC with the CLV Setup interface to check the read result
Table 8
Fig. 7. Connection example: Result 1 output
Configuration of Result 2 (pin 13/terminal 13) and Result 3 (pin 3/terminal 3): as Result 1 output
V
S
= depending on
operating voltage applied
(+4.5...+30 V DC)
„Result 1“
V
S
V
o
CLV 41x
Pulse duration:
10 ms ... 9.9 s or static
(to end of next reading
pulse)
12
5
Terminal assignment
AMV 40-011/AMS 40-012, -013:
T. 12
T. 5
Result 1
GND