Operating Instructions
CLV 42x bar code scanner
I-4
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 981/O078/16-08-2004
Quick Finder
Installation procedure (overview)
Reading pulses via switching input "Sensor 1" (default setting)
1.
Check scope of delivery for completeness.
2.
Install the CLV at the reading station and align it with an object possessing a bar code.
3.
Install the CDB 420 or CDM 420 connection module.
4.
Connect the CLV to the CDB 420 or CDM 420 connection module.
5.
Install the reading pulse sensor.
6.
Connect the reading pulse sensor to the "Sensor 1" switching input in the CDB 420 or
CDM 420.
7.
Connect the host to the "host interface" in the CDB 420 or CDM 420.
8.
Switch on the power supply to the CDB 420 or CDM 420.
After the CLV has been started, the "Device Ready" LED lights up. The beeper signals
that reading mode has been started by means of two consecutive sounds.
9.
Switch on PC and start Windows
TM
(at least Windows 95
TM
required).
10. Install accompanying user software "CLV Setup" and online help "CLV Setup Help"
from CD-ROM (“Manuals & Software“) to PC.
11. Connect the PC to the terminal interface of the CLV.
For this purpose, connect the PC via a 3-core RS 232 data cable (null modem cable)
to the "Aux" plug in the CDB 420 or CDM 420.
12. Start "CLV Setup" user software.
CLV Setup starts the communication with the CLV and copies the parameter set of the
CLV via an upload. The parameter set is displayed on tabs.
13. Carry out a test read with the test bar code sample (clock the CLV accordingly).
Display the reading result in the terminal emulator of CLV Setup.
14. Configure the CLV for the application by means of the setting options on the tabs
in CLV Setup.
Copy the modified parameter set temporarily to the CLV via download.
Do not
switch off the power supply of the CDB 420 or CDM 420 (of the CLV)!
15. Run a test under realistic conditions.
16. Check proper data transfer of the CLV to the host.
17. Correct and optimize the set parameter values if necessary.
Copy the parameter set to the CLV
permanently
via download.
18. Save the parameter set as a "*.scl" configuration file in CLV Setup.
The CLV contains
application-specific
settings and is ready for operation.