Color of LED Status
Status
Light blue
–
UserDef1 (reserved)
Red
Blue
Flashes
alternately in
both colors
Firmware download
Red
ON
Firmware download:
Error: Completion not successful
3.5
Product features and functions (overview)
Table 5: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Security and ease of
use
•
Rugged, compact metal housing
•
Automatic self-test at system start
•
Diagnostic tools for system setup and (remote) system monitoring
•
Configurable output of reading diagnostic data
•
Operating data polling, in case of error, issue of error code if
required
•
Test string function (heartbeat) can be activated to signal that the
device is ready for operation
•
Password-protected configuration mode via SOPAS ET
•
Future-oriented due to firmware update (FLASH PROM) via data
interface
•
Future-oriented SOPAS ET configuration software
•
Low power consumption
Convenient operation/
configuration
•
Configuration via SOPAS ET configuration software (online/
offline) or commands
•
LED status indicators
•
Profile programming with bar codes, generated and printed via
SOPAS ET
•
Beeper for actuating the device function can be switched off
Read operation modes
•
Start/stop operation (one bar code bearing object per read cycle)
Read cycle
•
Pulse sources for start: Switching inputs, data interface (com‐
mand), auto pulse, free
•
Pulse sources for stop: Read cycle source, switching inputs, data
interface (command), timer, condition
Bar code evaluation
•
All current 1D bar code types
•
No. of codes per reading interval: 1 ... 15 (auto-discriminating)
Data processing
•
Influencing the output of the reading data by event-dependent
evaluation conditions
Data Communication
•
Host interface: A data output format can be configured for the
reading result, can be switched to various physical interfaces,
parallel operation possible
•
AUX interface: Fixed data output format
3.6
Operating principle
The CLV60x CMOS bar code reader detects bar codes in an illuminated scanning field
(scan line). The length of the scan line which can be used for evaluation (reading field
height) depends on the reading distance as a result of the V-shaped light emission.
The light pattern reflected from the bar code is recorded, processed, and decoded.
External sensors deliver information about the read cycle to control this process.
The read results are output to the device data interfaces and forwarded to a host/PC.
3
PRODUCT DESCRIPTION
12
O P E R A T I N G I N S T R U C T I O N S | CLV60x
8021817/10Y9/2018-09-14 | SICK
Subject to change without notice