The output of the read results is either carried out at the end of the read cycle (the rear
edge of the object has left the end of the reading field) or even during the read cycle if
certain configurable conditions are met.
Data
output
5
Trigger 2:
Stop
reading
2
Trigger 1:
Start
reading
3
R
e
a
d
ing
f
ie
ld
4
Start/Stop mode
1
Figure 4: Start/stop operating mode of the device in stand-alone operation
1
Start/stop operation
2
Trigger 2: Stop reading
3
Trigger 1: Start reading
4
Reading field
5
Data output
NOTE
The SOPAS ET configuration software can be used to configure the reading operation
mode.
3
PRODUCT DESCRIPTION
14
O P E R A T I N G I N S T R U C T I O N S | CLV60x
8021817/10Y9/2018-09-14 | SICK
Subject to change without notice