Table 1: Activities and technical requirements
Activities
Qualification
Mounting, maintenance
■
Basic practical technical training
■
Knowledge of the current safety regulations in the workplace
Electrical installation,
device replacement
■
Practical electrical training
■
Knowledge of current electrical safety regulations
■
Knowledge of the operation and control of the devices in
their particular application
Commissioning, configura‐
tion
■
Basic knowledge of the Windows
TM
operating system in use
■
Basic knowledge of the design and setup of the described
connections and interfaces
■
Basic knowledge of data transmission
■
Basic knowledge of bar code technology
Operation of the device for
the particular application
■
Knowledge of the operation and control of the devices in
their particular application
■
Knowledge of the software and hardware environment for
the particular application
2.7
Operational safety and particular hazards
Please observe the safety notes and the warnings listed here and in other chapters of
these operating instructions to reduce the possibility of risks to health and avoid dan‐
gerous situations.
The product is fitted with LEDs of the risk group 0. The accessible radiation from these
LEDs does not pose a danger to the eyes or skin.
WARNING
Electrical voltage!
Electrical voltage can cause severe injury or death.
■
Work on electrical systems must only be performed by qualified electricians.
■
The power supply must be disconnected when attaching and detaching electrical
connections.
■
The sensor must only be connected to a voltage source as set out in the require‐
ments in the operating instructions.
■
National and regional regulations must be complied with.
■
Safety requirements relating to work on electrical systems must be complied with.
WARNING
Dangerous equipotential bonding currents!
Improper grounding can lead to dangerous equipotential bonding currents, which may
in turn lead to dangerous voltages on metallic surfaces, such as the housing. Electrical
voltage can cause severe injury or death.
■
Work on electrical systems must only be performed by qualified electricians.
■
Follow the notes in the operating instructions.
■
Install the grounding for the product and the system in accordance with national
and regional regulations.
SAFETY INFORMATION
2
8021817/10Y9/2018-09-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV60x
9
Subject to change without notice