Reading field diagram
Resolution
a: 0.125 mm (4.9 mil)
b: 0.15 mm (5.9 mil)
0
0
c: 0.2 mm (7.9 mil)
d: 0.25 mm (9.8 mil)
e: 0.35 mm (13.8 mil)
f: 0.5 mm (19.7 mil)
f
e
a
b
d
c
Reading distance in mm (inch)
Reading field height in mm (inch)
40
(1.57)
30
(1.18)
20
(0.79)
10
(0.39)
–40
(–1.57)
–20
(–0.79)
20
(0.79)
40
(1.57)
60
(2.36)
–60
(–2.36)
80
(3.15)
70
(2.76)
60
(2.36)
50
(1.97)
Figure 17: CLV60x reading field diagram, relating to standard conditions
CLV60x reading field diagram standard conditions:
•
Code type 128 or 2/5 Interleaved
•
Bar code print contrast (PCS) > 90%
•
Tilt α reading angle 0°
•
Ambient light < 2,000 lx
•
Rate of successful reads (Good Read) > 75%
11.2
Performance
Bar code types
All common code types, Code 39, Code 128, Code 93, Codabar,
UPC / GTIN / EAN, 2/5 Interleaved
Print ratio
2:1 … 3:1
No. of codes per scan
1 … 1
No. of codes per reading
interval
1 ... 15 (auto-discriminating)
No. of characters per read‐
ing interval
450
Number of characters per
code
≤
30
Number of multiple read‐
ings
1 … 100
11
TECHNICAL DATA
36
O P E R A T I N G I N S T R U C T I O N S | CLV60x
8021817/10Y9/2018-09-14 | SICK
Subject to change without notice