Configuration
1)
Diagnostics
(local)
SOPAS ET
SOPAS ET
PC
CLV61x Dual Port
(CLV61x-Dx52x)
Aux (USB)
Host /Aux (Ethernet, port 2)
Host /Aux (Ethernet, port 1)
V
s
PROFINET
PROFINET
Read trigger
(switching input)
1
Scanner
2
Decoder
3
Interfaces
4
T distributor
2)
6
1) Alternative: GSD configuration (centrally via the PROFINET controller)
8
2) Male connector, M12, 4-pin, A-coded splitted to 2 x female connector M12, 5-pin, A-coded)
9
5
7
Figure 7: Block diagram for CLV61x-Dx52x
1
Read trigger (switching input)
2
Scanner
3
Decoder
4
Interfaces
5
Configuration or diagnostics (local)
6
T-connector
7
Supply voltage V
s
8
Alternative: GSD configuration (central via PROFINET controller)
9
Male connector, M12, 4-pin, A-coded, split into 2 x female connectors, M12, 5-pin, A-
coded
3.2.3
Product features and functions
Table 3: Overview of product features and functions of the device
Product feature/function
Characteristic
CLV61x DualPort bar code scanner
■
Fixed focus
■
Red light line scanner or grid scanner
■
Reading range: Long range, optimized for intralogistics applications
■
Medium resolution
■
Additional scan frequency range (400
Hz to 1,000
Hz)
■
Option to adapt to code print quality
■
Evaluation range of scan line can be limited
■
Trigger input, type-dependent (CLV61x-Dx52x)
3
PRODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | CLV61x Dual Port (PROFINET)
8017842/ZMG5/2017-06-12 | 8M_DR | SICK
Subject to change without notice