Storage temperature
Devices without integrated heating: ‒20
°C ... +70
°C
Devices with integrated heating: ‒35
°C ... +70
°C
Permissible relative humidity
90
%, non-condensing
Ambient light compatibility
2,000
lx, on bar code
Bar code print contrast (PCS)
≥
60
%
12.6
Reading fields
Table 16: Reading conditions for reading field diagrams
Characteristic
Value
Test code
Code 39/ITF
Print ratio
2:1
Print contrast
> 90%
Tilt
±10°
Ambient light
≤ 2,000 lx
Good read rate
> 75 %
12.6.2
Reading field diagrams
CLV615: Long Range
150
(5.91)
(5.91)
(
7.87)
(9.84)
(11.81)
(13.78)
(–5.91)
–150
100
(3.94)
(3.94)
(–3.94)
–100
50
(1.97)
(1.97)
(–1.97)
–50
0
Reading distance in mm (inch)
2
Resolution
3
b: 0.35 mm
(13.8 mil)
c: 0.50 mm
(19.7 mil)
0
50
100
150
200
250
300
350
Reading field height in mm (inch)
1
b
c
Figure 24: Reading field diagram: CLV615 with reading window on side
1
Reading field height in mm (inch)
2
Reading distance in mm (inch)
3
Resolution
TECHNICAL DATA
12
8017842/ZMG5/2017-06-12 | 8M_DR | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x Dual Port (PROFINET)
47