2
Safety information
2.1
Intended use
The device consists of a fixed mount bar code scanner of the product family CLV62x,
CLV63x or CLV64x in the Ethernet variant with a protective housing with enclosure
rating IP69K.
The protective housing comprises two parts:
•
Protective housing with a fixed mount bar code scanner permanently installed at
the factory
•
Accompanying protective double bushing including sealing material for the two
electrical connections
When using suitable cables and correctly mounting the protective double bushing, the
device is protected against water from high-pressure or steam cleaners and as well as
against dust. For the specification,
Conditions for specified enclosure rating
NOTICE
The following requirements must be met in order to achieve the IP69K enclosure rating:
•
Use only the connection cables specified by SICK.
•
Seal the two cable outlets at the protective double bushing with the corresponding
O-rings.
•
The recessed flat seal on the side facing the protective housing is undamaged.
The O-rings are included in the device scope of delivery and are matched to the outer
diameters of the plug connectors.
The device is an intelligent, opto-electronic SICK ID sensor and is used for automated,
fixed identification and decoding of bar codes on moving or stationary objects. The
device transmits the data content of the decoded bar codes to a higher-level control
(PLC) for coordinating further processing.
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.2
Improper use
■
The device must not be used in explosion-hazardous areas.
■
The protective housing of the factory-installed fixed mount bar code scanner must
not be opened.
■
The device does not constitute a safety-relevant device according to the EC Machi‐
nery Directive (2006/42 / EC).
■
Any other use that is not described as intended use is prohibited.
■
The use of mounting accessories not approved by SICK AG is at your own risk.
2.3
Cybersecurity
To protect against cybersecurity threats, it is necessary to continuously monitor and
maintain a comprehensive and holistic cybersecurity concept. A suitable concept com‐
prises organizational, technical, procedural, electronic, and physical levels of defense
and provides suitable measures for different types of risks. SICK's products and solu‐
tions must be viewed as a component of this concept.
Information on Cybersecurity can be found at:
SAFETY INFORMATION
2
8021479/19ZB/2021-10-29 | SICK
T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
7