6.3
Wiring notes
NOTICE
Faults due to incorrect wiring.
Incorrect wiring may result in operational faults.
■
For data transmission, use only screened cables with twisted-pair wires.
■
Follow the wiring notes precisely.
NOTE
Preassembled cables can be found online at:
b
b
b
All electrical connections of the device are configured as M12 round connectors or as a
cable with D-Sub-HD male connector. The IP65/IP69K enclosure rating is only achieved
with screwed plug connectors or cover caps.
6.4
Pin allocation of the connections
Device connections with cable and male connector (standard version)
5
6
11
10
15
1
Figure 25: Male connector, D-Sub-HD, 15-pin
Pin
Signal
Function
1
DC 18 ... 30 V
Supply voltage
2
RxD (AUX)
AUX interface (receiver)
3
TxD (AUX)
AUX interface (sender)
4
Sensor 2
Digital switching input (function adjustable, e.g. external
reading cycle)
5
GND
Ground
6
RD+ (RS-422/485)
Host interface (receiver)
7
RD– (RS-422/485);
RxD (RS-232)
Host interface (receiver)
8
TD+ (RS-422/485)
Host interface (sender)
9
TD– (RS-422/485);
TxD (RS-232)
Host interface (sender)
10
CAN H
CAN bus (IN/OUT)
11
CAN L
CAN bus (IN/OUT)
12
Result 1
Digital switching output, function can be set
13
Result 2
Digital switching output, function can be set
14
Sensor 1
Digital switching input for external reading cycle
15
SensGND
Common ground for switching inputs
Table 5: Standard version: Pin assignment on 15-pin D-Sub-HD male cable connector
6
ELECTRICAL INSTALLATION
36
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x
8019588/2017-01-20 | SICK
Subject to change without notice