1.
Press the return key for about 3 s. The device interrupts the current read mode,
switches off all LEDs and the bar graph and switches into button operating mode.
Starting now, the device ignores all external reading cycles. The device does not
output any read results via the host interface.
The beeper confirms this process with an ascending melody. The “Read diagn”
function, the first function, is preselected (LED flashes slowly).
2.
Press the arrow button repeatedly until the LED of the desired function flashes.
The device runs through all possible functions step-by-step without executing them
and then starts again from the beginning.
The beeper confirms every step with a tone.
3.
Press the return key to confirm the selected function.
The LED flashes faster, the beeper confirms start with a double beep.
The device executes the function and automatically returns to the read mode after
2 min.
The “TeachIn” function (for match code) as well as “Auto-setup” automatically
stops the device when it has successfully read the presented bar code. The
“Ready” LED then flashes green three times, the beeper confirms this with an
ascending melody.
4.
To abort the function manually, press the Return key again and hold for 3 seconds.
The beeper confirms the change with an ascending melody. The “Ready” LED
lights up again.
✓
The device is again ready for reading and is waiting for a reading cycle.
NOTE
With the Auto-setup function, makes sure the bar code is at the maximum distance to
be read from the device.
Func‐
tion
LED
Description
Read
diagn
Flash‐
ing
slowly
“Read diagnosis/Percentage evalua‐
tion” selected
In the “Percentage evaluation” oper‐
ating mode, the bar graph continu‐
ously shows the last calculated read
rate in % referring to the last 100
reads.
Flash‐
ing rap‐
idly
“Read diagnosis/Percentage evalua‐
tion” started
TeachIn Flash‐
ing
slowly
“TeachIn match code” selected
Reads a match code which is used
as a reference object for additional
readings.
Flash‐
ing rap‐
idly
“TeachIn match code” started
Auto-
setup
Flash‐
ing
slowly
“Auto-setup” selected
Sets the most important parameters
of the device using a default bar
code.
Note: Present the reference bar code
at the maximum reading distance.
“Laser” LED differs from the function
in read mode!
Flash‐
ing rap‐
idly
“Auto-setup” started
Adjust‐
ing
Flash‐
ing
slowly
“Adjusting” (adjustment aid) selected Halves the scan line for aligning the
device to the center of the reference
bar code.
Flash‐
ing rap‐
idly
“Adjusting” (adjustment aid) started
Table 11: Meaning of the LEDs when buttons are actuated
OPERATION
8
8019588/2017-01-20 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x
53
Subject to change without notice