CDM490-0001
“Sensor 2 ... 6”
“Host 1” (serial)
“Aux 1” (serial)
“Result 1 ...4”
“CAN_2”
“CAN_1”
“U
V
”
“Sensor 1”
“Ext. input 2”
*)
“Ext. input 1”
*)
“Sensor 1 ... 6”
“AUX”
PLC
CAN bus 1
PLC
“Result 1”
“Result 2”
PLC
PLC
“Result 3”
“Result 4”
PLC
PLC
“Ext. output 1”
*)
“Ext. output 2”
*)
Connection module
CDM490-0001
Other
functions
CAN bus 2
“HOST 1” (serial)
“AUX 1” (serial)
RS-232
CMC600
*) For the additional use of the external switching inputs and outputs, the optional CMC600 parameter memory module is required.
Further data
processing
*)
RS-232/422/485
U
V
U
V
= DC 18 ... 30 V (CLV69x-xxx0)
U
V
= DC 21.6 ... 28.8 V (CLV69x-xxx1)
Decoder
Scanner
Interface
CLV69x-xxx0 (without heating)
CLV69x-xxx1 (with heating)
Cloning plug
no. 2062450
Configuration
Diagnostics
PC
HOST/PLC
Photoelectric
sensor
Read cycle end
(alternative)
Incremental
encoder
Route increment
Photoelectric
sensor
Read cycle
Figure 38: Connection of the device to the CDM490-0001 connection module
6.6
Wiring interfaces
6.6.1
Connecting the supply voltage
Connecting supply voltage to devices without heating
NOTICE
Devices with integrated heating may only be connected to the supply voltage via the 5-
pin M12 male connector “CAN 1” of the cloning plug.
In order to do this, the steps for the commissioning of devices with integrated heating
must be followed.
The device must be connected to a power supply unit with the following properties:
•
Supply voltage DC 24 V ± 20% (stabilized safety extra low voltage SELV as per cur‐
rently valid standards)
•
The electricity source must be able to release 144 W power or a maximum of 6 A
for a short time. The switching on current of the device is a maximum of 5.5 A for
1 to 2 ms (depending on the length of the supply cable).
•
Additional 0.5 W output power when using the optional CMC600 parameter mem‐
ory module in the corresponding connection modules
Connecting supply voltage to devices with integrated heating
NOTICE
When connecting the supply voltage, no further external components may be con‐
nected to the cloning plug (e.g. fan, PC using serial interface).
ELECTRICAL INSTALLATION
6
8014396/ZMG8/2017-07-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV69x
45
Subject to change without notice