Position the brackets near the ends of the housing. For devices with a protective
field height > 300 mm, the distance between the bracket and the end of the
housing must not exceed 1/4 of the length of the housing. If the device is exposed
to strong vibrations during operation, mount the top bracket at a height where the
offset in the safety light curtain housing rests on the bracket (
3
).
3
b
Tightening torque for the screws used to mount the bracket: 5 Nm to 6 Nm.
Tightening torque for the screws used to secure the safety light curtain in the
bracket: 2.5 Nm to 3 Nm (
4
). Higher torques can damage the bracket, while lower
torques are not secure enough to prevent the safety light curtain from moving.
4
2,5 Nm -
3 Nm
5 Nm -
6 Nm
5