Table 6: System connection pin assignment (male connector, M12, 5-pin)
Pin
Wire color
1)
s
Sender
r
Receiver
1
Brown
+24 V DC (voltage supply
input)
+24 V DC (voltage supply
input)
2
White
Reserved
OSSD1 (output signal
switching device 1)
3
Blue
0 V DC (voltage supply
input)
0 V DC (voltage supply
input)
4
Black
Reserved
OSSD2 (output signal
switching device 2)
5
Gray
Not connected
Not connected
1)
Applies to the connecting cables recommended as accessories.
Further topics
•
"Integration in electrical control", page 22
6.3
System connection via connection cable (M12, 5-pin to 8-pin)
An optional connection cable is available to connect the 5-pin system connection to
an existing 8-pin female connector. The connection cable can be used to replace an
existing C2000 safety light curtain with a deTec2 Core , without having to route new
cables.
ELECTRICAL INSTALLATION
6
8014276/1DCM/2022-10-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec2 Core
43
Subject to change without notice