180˚
r
s
r
s
Figure 20: Sender and receiver must not be installed such that they are rotated 180° relative to
each other
Prerequisites
•
Project planning is completed.
•
Assembly is carried out according to the project planning.
•
Dangerous condition of the machine is and remains switched off during mounting.
•
The outputs of the device do not affect the machine during mounting.
•
Only use SICK-approved brackets for mounting.
•
Take appropriate measures for vibration damping if vibration and shock specifica‐
tions exceed the values and test conditions specified in the data sheet.
Notes on mounting
b
Mount the sender and receiver on a level surface (
1
).
1
b
Mount the sender and receiver such that a right-angled protective field is estab‐
lished, i.e. when mounted vertically at the same height. For minor adjustments
during alignment, the sender and receiver can be adjusted longitudinally in the
brackets (
2
).
MOUNTING
5
8014276/1DCM/2022-10-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec2 Core
31