Minimum
Typical
Maximum
Air humidity (non-condensing)
15%
95%
Storage temperature
-30 °C
+70 °C
Housing cross-section
31 mm × 34 mm, plus bracket,
Vibration resistance
4)
5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6)
Shock resistance
5)
15 g / 6 ms (EN 60068-2-27)
Class
3M4 (IEC TR 60721-4-3)
1)
Maximum permissible conductor resistance must be observed.
2)
The temperature difference between sender and receiver must not exceed 25 K.
3)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25
°C.
4)
Test conditions per axis: 1 octave/minute, 20 sweeps.
5)
Test conditions per axis: 200 shocks.
12.2
Response time
Table 15: Response time dependent on the protective field height
Protective field height in mm
Response time in ms
Resolution 14 mm
Resolution 30 mm
300
11
10
450
12
10
600
13
10
750
13
11
900
14
11
1050
15
11
1200
16
12
1350
17
12
1500
18
13
1650
19
13
1800
20
13
1950
21
14
2100
22
14
12.3
Power consumption
Table 16: Power consumption for sender and receiver
Protective field
height in mm
Typical power consumption for
sender in W
Typical power consumption for
receiver in W
1)
Resolution
14 mm
Resolution
30 mm
Resolution
14 mm
Resolution
30 mm
300
0.96
0.82
1.92
1.63
450
1.08
0.86
2.16
1.73
600
1.20
0.91
2.40
1.82
750
1.32
0.96
2.64
1.92
900
1.44
1.01
2.88
2.02
1050
1.56
1.06
3.12
2.11
1200
1.68
1.10
3.36
2.21
12
TECHNICAL DATA
58
O P E R A T I N G I N S T R U C T I O N S | deTec2 Core
8014276/1DCM/2022-10-27 | SICK
Subject to change without notice