42
8011952/YWL2/3-0/2016-08| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200
Subject to change without notice
3
ASSEMBLY AND INSTALLATION
3.2.5
Fitting the weatherproof cover
Weatherproof cover for analyzer
Assembly
▸
Push the base plate (2) sideways on the flange with tube (5), slot onto the threaded bolts
(4) of the duct-side surface of the flange plate and screw tight (
proof cover for analyzer (dimensions in mm)”, page 42
).
▸
Put the cover (1) on from above.
▸
Insert the side holding catches (3) into the counterpieces, twist and lock in.
Fig. 22: Fitting the weatherproof cover for analyzer (dimensions in mm)
Weatherproof cover for external purge air unit
The weatherproof cover (
see “Weatherproof covers”, page 121
) comprises a cover and
locking set.
Assembly:
▸
Mount the locking pins from the locking set on the base plate.
▸
Put the weatherproof cover on from above.
▸
Insert the holding catches into the counterpieces from the side, twist and lock in.
Clearance to lift off
(492)
(365)
(239)
> 25
0
(360)
A
A
A -A
Cover
Base plate
Side holding catches
Threaded bolts
Flange with tube
Duct