Technical information
Chapter
4
EFI
8012622/Z098/2016-11-07
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
27
Subject to change without notice
Technical realization
Control feature
Meaning/effect
Bypass B1 [In Bypass 1]
•
Logical 1, stimulates bit B1 for the key-
operated pushbutton for bypass
Bypass B2 [In Bypass 2]
•
Logical 1, stimulates bit B2 for the key-
operated pushbutton for bypass
Operating mode 1 [In A1]
•
Logical 1, switches to operating mode 1 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Operating mode 2 [In A2]
•
Logical 1, switches to operating mode 2 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Operating mode 3 [In A3]
•
Logical 1, switches to operating mode 3 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Operating mode 4 [In A4]
•
Logical 1, switches to operating mode 4 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Operating mode 5 [In A5]
•
Logical 1, switches to operating mode 5 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Operating mode 6 [In A6]
•
Logical 1, switches to operating mode 6 of the
C4000
•
Logical 0, makes it possible to select a
different operating mode
Overrun monitoring SCC [In SCC]
•
Logical 1, stimulates the SCC bit for overrun
monitoring on the C4000
Bottom dead center BDC [In BDC]
•
Logical 1, stimulates the BDC bit for PSDI
integration on the C4000
Top dead center TDC [In TDC]
•
Logical 1, stimulates the TDC bit for PSDI
integration on the C4000
I/O error [I/O Error]
•
Logical 0, if there is no error on a connected
device
•
Logical 1, if there is an error on a connected
device
19)
If two bits are logical 1, there will be an error on the C4000.
Tab. 14: Control features on
the C4000 (data
to the
C4000)