Monitored event
Configurable User
Warning parameters
Default
value
Notes
Default
activation
state
High gas velocity VOG limit
45 m/s
If the current average Velocity of Gas exceeds the value "VOG
limit", a User Warning is generated.
Caution:
This parameter (Reg. #7201"MaxVelGas") also defines the
upper limit of the gas velocity range classes for the Diagnostics
Comparison Log. Changes to this parameter will clear all data
from the Diagnostics Comparison Log.
Configure "VOG limit" to suit the specific application.
Off
Power supply
(low input voltage)
Input voltage warning 12000mV
If the power supply voltage drops below the value "Input volt-
age warning" (e.g. in applications with autarkic power supply
by solar panels) a User Warning is generated.
Off
A Logbook is full
of unackn. entries
Logbook full of unack. entries
If one of the logbooks is full of unacknowledged entries, a User
Warning is generated.
Off
Meter is in Config-
uration Mode
Warning at Configuration Mode
If the meter is in Configuration Mode, a User Warning is gener-
ated.
Off
Battery lifespan
Warning if battery lifespan is low
If the remaining battery lifespan is less than 15%, a User Warn-
ing is generated.
On
1
User Warnings must be activated to become effective on the warning output.
2
These user warning limits are only monitored, as long as certain preconditions are met (see
Table 22).