Maintenance
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
171
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
6.2.2
Checking the meter health
The FLOWSIC600 monitors its own meter health with User Warnings and system alarms. If
the outputs are configured to indicate alarms and / or User Warnings, it is not necessary to
manually check the meter health.
To get visual feedback about the meter‘s health, the "Main system bar" in MEPAFLOW600
CBM provides a compact overview:
Use MEPAFLOW600 CBM to connect to the meter (
).
Check the main system bar for any yellow or red icon (
). A red or yellow icon
indicates a potential problem with the meter.
If any of the icons in the main system bar are yellow or red, proceed with checking the
"Meter Status" (
) and the "User Warnings" (
).
Figure 80
Main system bar
Main system bar
Measured SOS
Icons for system alarms, User
Warnings and performance