Appendix
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
207
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
Figure 97
Common key code (for short description of meter design, indicated on Type Plate* and Instrument Data Sheet**)
** The Instrument Data Sheet is included in the Manufacturer Data Report (MDR).
Type Code FLOWSIC600
Group
7
8
10
12
13
14
15
FL600-
-
-
METER BODY
Path configuration
1-Path
1
P
2-Path
2
P
4-Path
4
P
1+1-Path redundant
1
R
2+2-Path redundant
2
R
4+4-Path (Quatro)
4
R
4+1-Path (2plex)
5
C
2-Path crossed
2
X
4-Path crossed
4
X
2-Path Special
2
S
Overall length
2D 2
D
3D
3
D
4D
4
D
5D
5
D
6D
6
D
Shortened Meter body
S
D
Other size
X
D
Nominal size
2" / DN 50
0
2
3" / DN 80
0
3
4" / DN 100
0
4
6" / DN 150
0
6
8" / DN 200
0
8
10" / DN 250
1
0
12" / DN 300
1
2
16" / DN 400
1
6
Other size
#
#
Connection flange type
ASME B16.5 / ASME B16.47 (>24")
C
L
#
#
#
#
DIN EN 1092-1
P
N
#
#
#
#
GOST 12815-80 / 12821-80 / GOST-R 54432-2011
P
N
#
#
#
#
NORSOK L 005
N
K
#
#
#
#
TECHLOK
I
N
X
X
#
#
Grayloc
G
R
X
X
#
#
EN 1759-1
C
L
#
#
#
#
Other type
X
X
X
X
X
X
Connection diameter
Schedule ####
S
C
#
#
#
#
Specified in [mm] (DIN)
#
#
#
#
.
#
Flange type / sealing face
Raised Face (ASME B16.5 / B16.47)
R
F
Ring Type Joint (ASME B16.5 / B16.47)
R
J
Form B1 (EN 1092-1 / 1759-1)
B
1
Form B2 (EN 1092-1 / 1759-1)
B
2
Form # Inlet / Form # Outlet (EN 1092-1 / 1759-1)
#
#
Version V# (GOST 12815-80 / 12821-80)
V
#
Type T# (GOST-R 54432-2011)
T
#
Special design
X
X
Material
Carbon Steel
0
Stainless steel
1
LT-CS
2
Duplex
3
Superduplex
4
Superaustenit
5
Aluminium
6
Other material
X
Connection for Extraction Tool
Yes
Y
No
N
9
ULTRASONIC TRANSDUCER
(Will be selected by SICK on the basis of the technical data )
_
_
SIGNAL PROCESSING UNIT
Ex-proof-design
None
0
CSA Group D T4
1
CSA Group B, C, D T4
2
ATEX IIA T4, M20x1.5
3
ATEX IIC T4, M20x1.5
4
ATEX IIA T4, 1/2 NPT
5
ATEX IIC T4, 1/2 NPT
6
IECEx IIA T4, M20x1.5
7
IECEx IIC T4, M20x1.5
8
IECEx IIA T4, 1/2 NPT
9
IECEx IIC T4, 1/2 NPT
A
11
Power supply
12 ... 24V DC
D
C
Data outputs
Hardware variant 1 (4 digital outputs)
1
Hardware variant 2 (1 analog current output and 3 digital outputs)
2
Hardware variant 4 (1 analog current output and 2 RS485)
4
Hardware variant 5 (with integrated EVC, p- and T-transmitters externally power supplied, I/O board with DSP)
5
Hardware variant 6 (with integrated EVC, p- and T-transmitters internally power supplied, I/O board with DSP)
6
Hardware variant 7 (same as hardware variant 1, but with LowPressureAnalogBoard)
7
Hardware variant 8 (same as hardware variant 2, but with LowPressureAnalogBoard)
8
Hardware variant 9 (same as hardware variant 4, but with LowPressureAnalogBoard)
9
Hardware variant A (same as hardware variant 5, but with LowPressureAnalogBoard)
A
Hardware variant B (same as hardware variant 6, but with LowPressureAnalogBoard)
B
HART-Protocol
(By selection of hardware variant 2 and 8 only)
Yes
Y
No
N
Front panel
LED SICK
0
LCD SICK
1
Custody transfer design meter
*
Yes
Y
No
N
# … to be specified by SICK
*
… only design of USM, no restriction to type approval
( 4P; 5C; 4R --> Y / other path configurations --> N)
E_69423
4
2
10
15
14
13
12
9
Key code
1
5
6
8
7
3
11
5
6
1
2
3
4
Rev. 1.12
2013/05