234
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Appendix
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
9.4
Logbooks
1
Classification of logbook entries
The entries are distinguished into three classes and identified by the initial character in the
first line.
●
"I"information
●
"W"warning
●
"E"error/ malfunction
2
Type of occurrence
●
"+"point of time identifying the beginning of a status
●
"-"point of time identifying the end of a status
9.4.1
Overview of event entries in meter logbooks
Message No.
on LCD
Details
Logbook LCD Text
Custody logbook [1]
3002
NO DSP communication
1
E+System 0001
NO DSP-Communic.
E-System 0001
NO DSP-Communic.
3003
Measurement invalid
1
E+DSP 0001
Reading invalid
E-DSP 0001
Reading invalid
3004
Firmware CRC invalid
1
E+Firmware 0001
CRC invalid
E-Firmware 0001
CRC invalid
3005
Parameter CRC invalid
1
E+Parameter 0001
CRC invalid
E-Parameter 0001
CRC invalid
3006
Parameter out of range
1
E+Parameter 0001
#XXXX range error
E-Parameter 0001
#XXXX range error
3007
Failure during storage of path compensation
parameter
1
E+PathComp. 0001
Storage error
E+PathComp. 0001
Storage error
3008
Meter clock time invalid
1
E+System 0001
ClockTime inval.
E-System 0001
ClockTime inval.