48
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Product Description
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
2.8.3
DataLogs
1
For firmware version 3.4.03 and higher, the FLOWSIC600 provides two DataLogs (Hourly
Log and Daily Log). They save averaged measured values and are stored in the SPU‘s non-
volatile memory (FRAM). All data can be downloaded and exported to Excel files with
MEPAFLOW600 CBM (
.).
2.8.3.1
Hourly Log
The Hourly Log logs hourly diagnostic values by default (dataset type "Diagnostic Values",
see Technical Information
) for the forward flow. As long as the flow is valid
and the VOG is above Vmin all diagnostic and flow values are averaged over one hour and
saved every full hour. The Hourly Log stores these values for more than a month (38 days)
by default. They are then overwritten with new values.
2.8.3.2
Daily Log
The Daily Log logs the daily volume counter values by default (dataset type "Volume Coun-
ters" see Technical Information
) for the forward flow. All flow values are
averaged over one day and saved at the (configurable) Accounting Hour (see Technical
Information
). The Daily Log stores these values for approximately 2 years by
default (1 year and 361 days). They are then overwritten with new values.
DataLog Storage Cycle
Hourly Log and Daily Log can be configured to save entries in a storage cycle of: 3 min, 5
min, 15 min, 30 min, 1 hour, 12 hours or 24 hours.
If a DataLog is set to a Storage cycle of 12 or 24 hours, the accounting hour takes effect.
2.8.3.3
DataLog storage behavior
Hourly Log and Daily Log can be configured for the following storage behavior:
●
Overflow (Default)
●
Stopping
1 This feature may be deactivated. Please contact your SICK representative.
The following sections describe the default configuration of the DataLogs. The
DataLogs can be configured to best suit your application
.
Storage Behavior "Stopping"
If a DataLog is configured with the storage behavior "Stopping", a warning will
be shown in the Meter Status Table when the DataLog is full. See
.