208
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Appendix
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
9.1.4
Technical data
Table 26
Common meter sizes and flow rates
Type approval
The information in this section may differ from the type approval which is valid
for the FLOWSIC600 in your country.
Please use your national type approval for the FLOWSIC600.
Nominal Size
Actual flow rate
[m
³
/h]
Actual flow rate
[ft
³
/h]
Max. Velocity*
Q
min
Q
t
Q
max1
1
Q
max
can be limited by the working pressure and attenuation of the gas medium
Q
min
Q
max
[m/sec] [ft/sec]
DN 50
(NPS 2)
4
13
400
140
14,000
65
213
DN 80
(NPS 3)
8
32
1000
280
35,000
65
213
DN 100
(NPS 4)
13
50
1,600
460
56,000
60
197
DN 150
(NPS 6)
20
80
3000
710
106,000
50
164
DN 200
(NPS 8)
32
130
4500
1,130
159,000
45
148
DN 250
(NPS 10)
50
240
7000
1,770
247,000
40
131
DN 300
(NPS 12)
65
375
8000
2,300
282,000
33
108
DN 350
(NPS 14)
80
375
10000
2,830
353,000
33
108
DN 400
(NPS 16)
120
600
14000
4,240
494,000
33
108
DN 450
(NPS 18)
130
650
17000
4,600
600,000
33
108
DN 500
(NPS 20)
200
975
20000
7,070
707,000
33
108
DN 600
(NPS 24)
320
1500
32000
11,300
1,131,000
33
108
DN 700
(NPS 28)
400
2000
40000
14,100
1,414,000
30
98
DN 750
(NPS 30)
400
2000
45000
14,100
1,590,000
30
98
DN 800
(NPS 32)
400
2400
50000
14,100
1,767,000
30
98
DN 900
(NPS 36)
650
3750
66000
23,000
2,333,000
30
98
DN 1000
(NPS 40)
650
5000
80000
23,000
2,828,000
30
98
DN 1050
(NPS 42)
1300
6000
85,000
46,000
3,004,000
30
98
DN 1100
(NPS 44)
1400
6500
90000
49,500
3,181,000
28
92
DN 1200
(NPS 48)
1600
7000
100000
56,600
3,535,000
27
89
*When a configuration with flow conditioner is used, the velocity of gas must
not exceed 40 m/s (131 ft/s) in the pipe.
TYPE APPROVAL