Criteria applicable to meter when used in accordance with metrological type approval
Table 28
Meter sizes according to metrological type approval
Meter
size
Meter size
Measuring range (Qmin [m³/h])
Max. flow
rate Qmax
[m³/h]
Meter
factor
[pulses/
m³]
1:100
1:80
1:50
1:30
1:20
DN 80
(3")
G100
8
160
45000
G160
8
13
250
28800
G250
8
13
20
400
18000
G400*
8
13
20
32
650
11100
DN 100
(4")
G160
13
250
28800
G250
13
20
400
18000
G400
13
20
32
650
11100
G650*
13
20
32
50
1000
7200
DN 150
(6")
G250
20
400
18000
G400
20
32
650
11100
G650
20
32
50
1000
7200
G1000
20
32
50
80
1600
4500
G1000E
32
2200
3272
G1600*
20
32
50
80
130
2500
2880
DN 200
(8")
G400
32
650
11100
G650
32
50
1000
7200
G1000
32
50
80
1600
4500
G1600
32
50
80
130
2500
2880
G1600E
32
40
3600
2000
G2500*
32
80
130
200
4000
1800
DN 250
(10")
G1000
50
80
1600
4500
G1600
50
80
130
2500
2880
G2500
50
80
130
200
4000
1800
G2500E
50
5000
1285
G4000*
50
80
130
200
320
6500
1110
DN 300
(12")
G1600
80
130
2500
2880
G2500
80
130
200
4000
1800
G4000
65
80
130
200
320
6500
1110
G4000 E
65
7800
920
DN 350
(14")
G1600
80
2500
2880
G2500
80
130
200
4000
1800
G4000
80
130
200
320
6500
1110
G4000 E
80
7800
920