Fig. 4-2:
Configuration Output of HC8XINIT.EXE
[w95] C:\WIN95>HC8Xinit /c1
Querying the HC8X...
Found:
Check sum : 99FC hex
BaudRate : 9600 Bd
Address : 48 dec, 30 hex
Function : HC
Correction: inactive
Programbl.: active
Gain : 1.00000
Offset : 0.00
Channel activity:
0:Enabled 1:Enabled 2:Enabled 3:Enabled 4:Enabled 5:Enabled 6:Enabled 7:Enabled
HC Mode :
0:H1 1:H1 2:H1 3:H1 4:H1 5:H1 6:H1 7:H1
TCtrl:
0:185.0 1:185.0 2:185.0 3:185.0 4:185.0 5:185.0 6:185.0 7:185.0
TLLim:
0: 12.0 1: 12.0 2: 12.0 3: 12.0 4: 12.0 5: 12.0 6: 12.0 7: 12.0
TULim:
0: 12.0 1: 12.0 2: 12.0 3: 12.0 4: 12.0 5: 12.0 6: 12.0 7: 12.0
THyst:
0: 5.0 1: 5.0 2: 5.0 3: 5.0 4: 5.0 5: 5.0 6: 5.0 7: 5.0
Remark :
Written:
BaudRate : 9600 Bd
Address : 48 dec, 30 hex
Function : HC
Correction: inactive
Programbl.: active
Gain : 1.00000
Offset : 0.00
Channel activity:
0:Enabled 1:Enabled 2:Enabled 3:Enabled 4:Enabled 5:Enabled 6:Enabled 7:Enabled
HC Mode :
0:H1 1:H1 2:H1 3:H1 4:H1 5:H1 6:H1 7:H1
TCtrl :
0:185.0 1:185.0 2:185.0 3:185.0 4:185.0 5:185.0 6:185.0 7:185.0
TLLim :
0: 12.0 1: 12.0 2: 12.0 3: 12.0 4: 12.0 5: 12.0 6: 12.0 7: 12.0
TULim :
0: 12.0 1: 12.0 2: 12.0 3: 12.0 4: 12.0 5: 12.0 6: 12.0 7: 12.0
THyst :
0: 5.0 1: 5.0 2: 5.0 3: 5.0 4: 5.0 5: 5.0 6: 5.0 7: 5.0
Remark :
Chapter
4
Technical Information
HC8X Heat Control
4-28
©
SICK AG · All rights reserved
8010043
Configuration and Addressing
4.4
Parameter Setting Example with HC8XINIT.EXE under
MS-DOS
In this example, the following parameters are to be transferred to the HC8X during the pro-
gram execution of HC8XINIT.EXE:
Enabling of channels 0, 1, 2, 3 and 5 (parameter:
/E25013
)
Channels 6 and 7 become followers (parameter:
/F67
)
Temperature values only for channels 1 and 2 (parameter:
/N10
)
Set temperature value of channels 1 and 2 = 107.6 C (parameter:
/T107.6
)
Upper limit temperature of channels 1 and 2 = 10 C (parameter:
/U10
)
Lower limit temperature of channels 1 and 2 = 20 C (parameter:
/L20
)
DOS environment variable "SET HC8XINIT= A little bit more complicated example" is to
be programmed as identification line of the HC8X.
The correct parameter transfer must be entered as a sequential string (see Fig. 4-3).
hc8xinit /c1 /e25013 /n10 /t107.6 /u10 /l20 /f67 /s