Chapter 10
Operating Instructions
ICR845-2 Image Code Reader
144
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8012377/ 0000/ 2008-01-30
Appendix
10.4.9
Transferring parameter sets between CLV-Setup and the ICR845-2
See
Chapter 6.8 Configuring the ICR845-2, Page 71
.
10.4.10 Unknown parameters
Upload vom ICR845-2
Uploading from ICR845-2
If the "CLV-Setup" program does not recognize the parameters or parameter values of the
ICR845-2 transferred during the upload, it outputs a warning message. Causes for unknown
parameters/values are e.g.: The ICR845-2 is a special device or the version of CLV-Setup is
older than the software of the ICR845-2. CLV-Setup displays the unknown parameters in the
window on the E
XTRAS
tab. The parameters are displayed in the form of command strings
and can be edited using the command string conventions. In this way, upward compatibility
with the ICR845-2 is ensured. When the parameter set is saved as a configuration file in
CLV-Setup, these parameters/values are also taken into account as with a download to the
ICR845-2.
Downloading to the ICR845-2
If the ICR845-2 does not accept individual parameters or parameter values in the parame-
ter set downloaded with CLV-Setup, it outputs a separate warning for each parameter on the
screen. This is due to the fact that one of the CLV-Setup software versions is newer than the
software in the ICR845-2, and it contains new parameters/values arising from the contin-
ued development of this ICR845-2 type. The effected ICR845-2 contains an older software
version which does not recognize these parameters/values, however.
We recommend that you check the effects of warnings in the ICR845-2 as follows:
1.
Check whether the ICR845-2 functions correctly after the parameter set is downloaded.
2.
Click
in the toolbar.
CLV-Setup loads the default settings from the database.
3.
Click
in the toolbar.
CLV-Setup uploads the problem parameter set from the ICR845-2.
4.
Click
in the toolbar.
CLV-Setup prints out the problem parameter set when you confirm the dialog box.
5.
Open the previous configuration file "* .scl" for the ICR845-2.
6.
Click
in the toolbar.
CLV-Setup prints out the problem parameter set when you confirm the dialog box.
7.
Compare the two parameter sets.
To restore the previous status, correct individual parameters in the problem parameter
set if necessary and download them to the ICR845-2 again.
Opening configuration files "*.scl"
Every time it loads configuration files, CLV-Setup checks whether it recognizes all the pa-
rameters/values.
If the program detects an error, it outputs a warning and enters the problem parameter/val-
ue in the window on the "E
XTRAS
" tab.