Operating Instructions
Symbology Reading Control
IDM corded & IDM Bluetooth
8017159/142O/2019-05-23
© SICK AG · Germany · All rights reserved · Subject to change without notice
49
3.7.4
Code 39/ Code 32
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
Code 39 Family Setting
SS Disable Code 39
0
SS Enable Code 39
1
SS Select Standard Code 39 as primary format
2
SS Select Full ASCII Code 39 as primary format
3
SS Select Code 32 (PARAF, Italian Pharmaceutical) as
primary format
4
SS Disable start/stop symbol transmission
5
SS Enable start/stop symbol transmission
6
SS Disable Code 32 leading A transmission
7
SS Enable Code 32 leading A transmission
8
SS Disable MOD 43 check digit verification
9
SS Enable MOD 43 check digit verification
A
SS Disable check digit transmission
B
SS Enable check digit transmission
C
SS Disable Code 39 buffering
D
SS Enable Code 39 buffering
E
Trioptic Code 39 Setting
SS Disable Trioptic Code 39
0
SS Enable Trioptic Code 39
1
Code 39 Min. Length
SS Default (01)
FIN
MS 01-98
(2 digits)
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
Code 39 Max. Length
SS Default (98)
FIN
MS 01-98
(2 digits)
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.