Operating Instructions
Symbology Reading Control
IDM corded & IDM Bluetooth
8017159/142O/2019-05-23
© SICK AG · Germany · All rights reserved · Subject to change without notice
53
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
UPC Supplement Settings SS Select UPC without supplement digits
0
SS Select UPC with only 2 supplement digits
1
SS Select UPC with only 5 supplement digits
2
SS Select UPC with 2/5 supplement digits
3
SS Disable force supplement digits output
4
SS Enable force supplement digits output
5
SS UPC Family Addenda Separator Off
6
SS UPC Family Addenda Separator On
7
UPC/ EAN Security Level
SS Level 0
0
SS Level 1
1
SS Level 2
2
Only available for UPC-A & EAN-13
Supplement Scan Vorting
SS None
0
SS Level 1
1
SS Level 2
2
SS Level 3
3
SS Level 4
4
SS Level 5
5
SS Level 6
6
SS Level 7
7
SS Level 8
8
SS Level 9
9
SS Level 10
A
SS Level 11
B
SS Level 12
C
SS Level 13
D
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
•
Level 0:
If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in
characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may
significantly impair the decoding ability of the scanner.
•
Level 1:
This is the default setting which allows the scanner to operate fastest, while providing
sufficient security in decoding “in-spec” UPC/EAN bar codes.