3.10.3
Bluetooth Batch Scanning
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
Batch Scanning Link
Control
SS Radio disable
0
SS Radio enable
1
Stored Data Transmission
SS Either on cradle or by scanning barcode
0
SS On cradle
1
SS Scan barcode
2
Delete Stored Data after
Transmission
SS Disable
0
SS Enable
1
Field Delimiter
SS None
0
SS ,
1
SS SPACE
2
SS
–
3
SS .
4
SS User define
5, [00-7F]
Batch Data Quantity
Output Format
SS As many times as the quantity indicates
0
SS <Quantity><Field Delimiter><Scanned Data>
1
SS <Scanned Data><Field Delimiter><Quantity>
2
Data Transmission Format
SS Disable (scanned data only)
0
SS Leading with MAC address (MAC address &
scanned data)
1
SS Leading with ID No. (Scanner ID & scanned data)
2
Only available for RS-232, USB HID and USB COM interface
in PAIR & PICO mode.
Batch Scanning Link Control
It’s a predefined radio option to control the radio-on or radio-off status under batch scanning operation.
Please note that if “Radio disable” is selected, the radio link will be disconnected once you enter batch
scanning. The radio link will be resumed when you transmit the stored data or exit batch scanning.