Stored Data Transmission
It’s a predefined approach when you want to transmit the scanned data under batch scanning operation. You
can transmit the scanned data by placing the scanner onto the cradle or scanning “Transmit Stored Data”
command (refer to chapter 2.7.3) or by either one of both methods.
Delete Stored Data after Transmission
This function is disabled in the factory default setting. The scanner will keep all stored data after transmission
until you scan the “Clear all Stored Data” command (refer to chapter 2.7.4). If you enable this function all
stored data will automatically be deleted after transmission.
Field Delimiter
This function is used to separate the specific information and the scanned data into two fields. You can
choose the delimiter format.
Batch Data Quantity Output Format
If you want to input the quantity information of the scanned barcode data, you can enter the quantity from 1
to 9999 by scanning the quantity barcodes right after scanning the barcode data. The quantity information
will be stored into the memory storage together with the barcode data. There are three ways to output the
stored barcode data and quantity information. (Also refer to chapter 2.7.1)
Data Transmission Format
In PICO mode up to seven scanners can be connected to one smart cradle. The Data Transmission Format
helps to identify the source of the transmitted data. Example format: <MAC address><Field delimiter><Data>
or <ID><Field delimiter><Data>.