R
e
fe
re
n
c
e
M
a
n
u
a
l
ID
M
B
lu
e
to
o
th
Configure Your IDM BT
8014563/VP14/2011-11-30
© SICK AG · Germany · All rights reserved · Subject to change without notice
49
S
S
S
S
PROGRAM
Serial Interface Control
♦
♦
♦
♦
Record Suffix, Preamble ,Postamble Setting
♦
♦
♦
♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
STX/ETX Control
SS
SS
Disable STX/ETX transmission
Enable STX/ETX transmission
STX/ETX is two characters used to indicate the starting and ending of the total data
frame transmitted via serial interface.
0
1
Record Suffix
SS
SS
SS
SS
SS
SS
MS
None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
SPACE (20H)
User defined character (1 character)
0
1
2
3
4
5
6, (00-7F)
Preamble
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Postamble
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
FIN
[00-7F], [FIN]
Serial Interface Message String (RS232, USB COM) :
STX
Preamble
Data Length
Prefix Symbol ID
Scanned Data
Suffix Symbol ID
Postamble
ETX
Record Suffix
1 character
1-15 characters
2-3 digits
1 or 2 characters
Variable length
1 or 2 characters
1-15 characters
1 character
1 character