Technical specifications
9
Technical specifications
9.1
Data sheets
9.1.1
Data sheet for the laser measurement sensor LD-MRS
Type
LD-MRS400001
(Standard)
LD-MRS400102
(Heavy-Duty)
LD-MRS420201
(UAV)
LD-MRS800001
(S
tandard-Version up to 8 layers)
Part No.
1045046
1047145
1085081
1069408
Distance measurement range 0.3 to 50 m (0.9 to
164 ft) to 10 %
remission
0.3 to 30 m (0.9 to
98.4 ft) to 10 %
remission
0.3 to 30 m (0.9 to
98.4 ft) to 10 %
remission
0,3 ... 50 m auf 10 % remission
Scan planes
4, vertical aperture angle over 4 planes: 3.2°
8 scan planes, vertical aperture
angle over 8 layers: 5,6° ±0,2°
4,2° (±0,2°) @ 50° scan angle
5,6° (±0,2°) @ 0° scan angle
6,4° (±0,2°) @ -50° scan angle
Usable horizontal aperture
angle (sector)
4 scan planes: 85° + 2 scan planes: 110°; overlapping ranges 8 scan angles: 85° + 4 scan angles:
110°; overlapping ranges
Angular resolution (step width) Min. 0.125° (interlaced) / 0,25° / 0,5°
Scanning frequency
Measuring mode: 12.5 Hz (0.125 ... 0.5°)/12.5 Hz (0.25°)/25
Hz (0.25°)/50 Hz (0.5°)
Field monitoring: 12.5 Hz (0.25°)/25 Hz (0.25°)/50 Hz (0.5°)
Measuring mode: 12,5 Hz (0,125 ...
0,5°)/12,5 Hz
(0,25°)/25 Hz (0,25°)/50 Hz (0,5°)
Tracking: 12,5 Hz (0,25° / focussed
(0,125 ... 0,5°) /
Flexible resolution (0,125 ... 0,5°)
Measurement resolution
40 mm (1.58 in)
Statistical error (1 sigma)
100 mm (3.94 in)
Beam divergence
Horizontal 0.08°, vertical 0.8° per layer, per laser 1.6°
Echoes per individual mea-
surement
3
Field monitoring
16 evaluation fields/instances, 1 of 3
evaluation strategies per field, 2 logical
inputs, 10 logical outputs (AND or OR link
to evaluation instances)
no field monitoring
Power-up delay
15 s (at an operation environment temperature of 20 °C (+68 °F))
Light sources
2 laser diodes, infrared light (895 to 915 nm)
Laser safety class of the unit
Class 1 acc. EN 60825
-1:2014
, 21 CFR 1040.10 and 1040.11
Optical indicators
None
Configuration
Measuring mode: with SICK LaserView Customer Edition visualization tool or messages
Field monitoring: with SOPAS-ET configuration software
Switching inputs/outputs
Measuring mode: none
Field monitoring: 2 inputs/10 outputs
(realized externally with a maximum of
two optional CAN modules with 8 configu-
rable I/O ports)
no switching inputs/outputs
Ethernet data interface
100 Mbit, TCP/IP, full duplex, measurement output for measuring mode
Data interface RS-232
Auxiliary interface, 57.6 KBd, 8 data bits, no parity, 1 stop bit (values cannot be modified)
Data interface CAN
500 KBit/s (fest), address range 0 to 127, max. line length: 100 m (328 ft)
Tab. 9-1: Technical specifications LD-MRS