Chapter
6
Operating Instructions
Laser measurement sensor LD-MRS
82
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8012948/ZMQ0/2017-06-09
Commissioning and configuration
•
Establish communication with the LD-MRS
•
Password-protected configuration with different operating levels
•
Diagnosis of the LD-MRS
6.2.1
System prerequisites for the SOPAS-ET
•
Standard Intel Pentium computer or compatible, at least a Pentium III, 500 MHz
•
Minimum of 512 MB RAM, 1024 MB RAM recommended
•
Data interface RS
232, Ethernet or CAN
•
Operating system: MS Windows 2000, XP, VISTA or Windows 7
•
Monitor with at least 256 colors, recommended: 65,536 colors (16 Bit High Color)
•
Minimum screen resolution: 800 × 600
•
Hard disk: minimum of 300 MB free memory
•
CD drive
6.2.2
Installation of SOPAS-ET
1. Start the computer and insert the installation CD
2. If the installation does not start automatically, call up "setup.exe" on the CD.
3. To complete the installation, follow the operation instructions.
6.2.3
Default setting of SOPAS-ET
6.3
Establish communication with the LD-MRS
Important
To communicate via TCP
IP, the TCP
IP protocol must be active on the computer.
When connecting a computer to the host, maintain the following sequence:
1. Turn on the computer.
2. Connect the computer to the LD-MRS using a data cable.
3. Switch on the supply voltage of the LD-MRS.
The LD-MRS runs a self test and initializes itself.
6.3.1
Connect the data interfaces
Connect the computer to the LD-MRS using an ethernet cable.
Parameter
Value
Language of the user interface
English (the program needs to be re-started after a
change)
Units of length
Metric
User group (operating level)
Maintenance staff
Download the parameters for the LD-MRS Immediately when there is a change, temporary in the
RAM of the LD-MRS
Upload the parameters of a LD-MRS
Automatic after going online
Window partitions
3 (Project tree, help, work area)
Serial communication
COM1: 9,600 Bd/19,200 Bd, 8 data bits, no parity,
1 stop bit
Tab. 6-1: Default setting of SOPAS-ET