Device
1
CDM420-0006
Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
12
1
9
7
6
34
T
‒
/TxD
35
R
‒
/RxD
36
GND
6
Shield
RS-232
RS-232
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF
ON
2
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1
10
15
6
11
5
4
3
Figure 40: Wiring data interface RS-232 of the device in connection module CDM420-0006.
1
Device
2
Adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-coded)
3
Connection module: female connector, D-Sub-HD, 15-pin
4
Connecting cable permanently connected with the device (male connector, M12, 17-pin, A-coded)
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g., the
configuration software SOPAS ET.
13.4.5
Wiring the CAN interface of the device in the CDM420-0006
Device = Lector61x = V2D61xx-xxxxxEx
Not considered: connection and looping through of the supply voltage, connection of a trigger sensor for read cycle
generation (e.g. at the master)
13
ANNEX
74
O P E R A T I N G I N S T R U C T I O N S | Lector61x
8024830/1FGB/2022-03-29 | SICK
Subject to change without notice