Active
parameter is used to select the event that activates the digital output.
•
SOPAS COMMAND
: The output can be activated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
•
DEVICE READY
: The output is activated as soon as the sensor is ready for use.
•
GOOD READ
: The output is activated if the read operation was successful.
•
NO READ
: The output is activated if the read operation was unsuccessful.
•
TEACH-IN 1 OK
: The output is activated if the
MATCH CODE TEACH-IN 1
has been success‐
fully taught in.
•
TEACH-IN 1 NOK
: The output is activated if the
MATCH CODE TEACH-IN 1
could not be suc‐
cessfully taught in.
•
TEACH-IN 2 OK
: The output is activated if the
MATCH CODE TEACH-IN 2
has been success‐
fully taught in.
•
TEACH-IN 2 NOK
: The output is activated if the
MATCH CODE TEACH-IN 2
could not be suc‐
cessfully taught in.
•
EXTERNAL ILLUMINATION
: External lighting is connected to the output and can be
switched on and off by the device.
•
MATCH 1 CONDITION
: The output is activated if the code that has been read corre‐
sponds to the
MATCH 1 CONDITION
match code.
•
MULTICODES1 CONDITION
: The output is activated if the number of codes that have
been read corresponds to the number specified by the
MULTICODES1 CONDITION
.
•
TEACH-IN1 CONDITION
: The output is activated if the code that has been read corre‐
sponds to the
TEACH-IN1 CONDITION
match code.
•
TEACH-IN2 CONDITION
: The output is activated if the code that has been read corre‐
sponds to the
TEACH-IN2 CONDITION
match code.
NOTE
The behavior of the external illumination and the switch type are set under
.
Inactive
parameter is used to select the event that leads to the digital output being
deactivated.
•
TIMER/TRACKING
: The output is deactivated on expiry of a specific period (
•
NEXT OBJECT TRIGGER
: The output is deactivated as soon as the next reading gate
opens.
•
SOPAS COMMAND
: The output can be deactivated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
•
GOOD READ
: The output is deactivated if the read operation was successful.
•
NO READ
: The output is deactivated if the read operation was unsuccessful.
•
TEACH-IN 1START
: The output is deactivated as soon as the
MATCH CODE TEACH-IN 1
teach-
in process commences.
•
TEACH-IN 2START
: The output is deactivated as soon as the
MATCH CODE TEACH-IN 2
teach-
in process commences.
•
MATCH 1 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
MATCH 1 CONDITION
match code.
•
MULTICODES1 CONDITION
: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the
MULTICODES1 CONDITION
.
•
TEACH-IN1 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
TEACH-IN1 CONDITION
match code.
•
TEACH-IN2 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
TEACH-IN2 CONDITION
match code.
SOPAS PARAMETER OVERVIEW
22
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK