7
Focal length of lens, here example for f = 17.1
mm
8
Near range
Interpretation aid for the field of view diagram
Using the diagram, you can determine the following data for each device type:
•
The maximum working distance for a selected code resolution
•
The dimensions of the field of view that is available for this distance
7
0
200 x 160
400 x 320
600 x 480
800 x 640
1000 x 800
1200 x 960
0
200
400
600
800
1000
1200
1400
1600
1800
2000
a
b
Min. resolution in mm
3
1D code
4
2D code
5
0.4
0.6
0.8
0.1
0.3
0.5
0.7
0.9
1.1
1.3
0.2
1.2
1.4
1.6
1.0
a: f = 9.6 mm
b: f = 17.1 mm
Working distance/focus position in mm
6
Field of view in mm²
1
Complete area
2
8
9
ß
Figure 13: Interpretation aid for the field of view diagram
1
Field of view in mm
2
2
Overall range
3
Minimum resolution in mm
4
1D code
5
2D code
6
Working distance/Focus position in mm
7
Selected code resolution
8
Focal length of lens, here example for f = 9.6 mm
9
Reading off: resultant maximum working distance
ß
Reading off: resultant field of view (mm x mm)
Given (in red):
•
Code resolution 2D code
7
: 1.0 mm
•
Focal length of lens
8
: 9.6 mm
Read off (in green):
•
Maximum working distance
9
: approx. 920 mm
•
Field of view
ß
: approx. 640 mm x approx. 510 mm