13.4.9
Wiring the digital outputs “Result 1” to “Result 4” of the device in the CDB650-204
Device = Lector621 = V2D621x-xxxxxYx (Y = B or C)
Device
1
CDB650-204
Load (e.g. PLC)
4
Cable
3
B
1
.
.
.
D
22
GND
5
Shield
U
IN
*
V
S
GND
V
out
Result
A
GND
B
1
2
2
For inductive load:
6
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
RES/OUT
C
8
7
2
5
Figure 46: Wiring the digital outputs “Result 1” to “Result 4” of the device in the connection module CDB650-204
1
Device
2
Supply voltage V
S
3
Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male connector, M12, 17-pin, A-coded)
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
7
Connection module: female connector, M12, 17-pin, A-coded
8
Device: male connector, M12, 17-pin, A-coded
Inductive load
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 39: Assignment of placeholders to the digital outputs
Device
CDB650-204
Output A
Pin B
Signal C
Terminal D
Result 1
13
RES/OUT 1
20
Result 2
14
RES/OUT 2
21
Result 3
16
RES/OUT 3
50
Result 4
17
RES/OUT 4
51
Characteristic data of the digital outputs
Table 40: Characteristic data of the digital outputs “Result
1” to “Result
4”
Type
Switching
13
ANNEX
86
O P E R A T I N G I N S T R U C T I O N S | Lector621
8022502/15NT/2020-02-11 | SICK
Subject to change without notice