3.4
Integrable illumination unit (optional)
For complete devices, the integrable illumination unit is already mounted. For basic
devices, the integrable illumination unit (VI55I ring illumination unit) can be ordered
and installed on your own.
1
2
3
1
2
Figure 3: VI55I ring illumination unit (integrable illumination unit)
1
6 LEDs
2
2 openings for the two laser alignment aids for aligning the device, can be deactivated
(color: visible red light)
3
1 feedback LED for the VI55I ring illumination unit (color: visible green light, for example
for Good Read; visible red light, for example for No Read).
NOTE
Set the display function of the feedback LED using the SOPAS ET configuration soft‐
ware. With the default device settings, the feedback LED briefly generates a green light
spot within the field of view of the device after a successful read.
3.5
Display and control elements
0
%
1
0
0
%
R
e
a
d
y
R
e
su
lt
|T
e
s
t
|T
e
a
c
h
|F
o
c
u
s
|S
e
tu
p
L
/A Gb
E
F
u
n
c
L
ig
ht
1
2
3
4
Figure 4: Status LEDs, bar graph display and function keys on the top of the device
1
Arrow pushbutton
2
Return pushbutton
3
Bar graph display
4
Status LEDs
Status indicators
Table 4: First display level
Display LED
Color
Status
Ready
O
Green
Device ready for operation
O
Red
Hardware or software error
Result
O
Green
Read operation successful
O
Red
Read operation unsuccessful
Light
O
Green
Read mode: illumination on, internal reading interval open
O
= illuminated;
Ö
= flashing
PRODUCT DESCRIPTION
3
8018071/1E1C/2021-12-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
17
Subject to change without notice