Ready
LED
Device status
Remarks
Green com‐
ponents
Red compo‐
nents
O
Ö
Red compo‐
nents flash
cyclically
The device status in
the PROFINET network
depends on the flashing
frequency of the red LED
components.
Flashes
every 7 sec‐
onds
Network detection in the
device is active.
After switching on, the device detects
a PROFINET network and activates
the PROFINET protocol. The dura‐
tion of network detection can be
configured in SOPAS ET (default:
3 minutes). Network detection can
be deactivated in SOPAS ET.
Flashes
every
0.5 seconds
PROFINET is activated in
the device. The device is
not connected to the PLC
or the device is not config‐
ured.
Ö
Ö
PROFINET is activated in
the device.
Prerequisite: the “Flashing” function
was activated for the device in the
configuration software of the PLC
(device identification).
O
= lights up;
Ö
= flashes;
o
= does not light up
3.6
Memory card
NOTICE
Risk of damage to the memory card!
b
To avoid damaging the microSD memory card, make sure the device is
de-ener‐
gized
when you insert or remove the card. For this purpose, disconnect the device
from the supply voltage.
NOTICE
Loss of configuration data
Do not remove the memory card or switch off the supply voltage while the parameter
set is being saved. Otherwise all parameters not yet saved permanently will be lost.
The device has a card slot for a microSD memory card integrated in the housing.
The microSD memory card is optional and not included in the scope of delivery of
the device. To ensure that the memory card functions reliably, only use card types
(industrial standard) approved by SICK. These can be found as accessories on the
product page in the Internet,
. The memory card has no
write protection that can be activated.
Functions
An inserted memory card serves as a local external storage medium for the device
outside the internal device memory,
see "Initial commissioning", page 54
.
PRODUCT DESCRIPTION
3
8018071/1E1C/2021-12-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
19
Subject to change without notice