Customer-supplied mounting system
A customer-supplied mounting system must meet the following requirements:
•
The device can be aligned in the X- and Y-axes.
•
The mounting system must be able to bear the weight of the device and connect‐
ing cables without shock.
•
In mounting situations with strong vibrations, it may be necessary to provide shock
mounts.
•
Mounting options for the device using the threaded mounting holes or sliding nuts
must be available.
5.4
Mounting the optics
NOTE
This mounting step is only required for the Lector6xx Flex (basic device) device variant.
NOTICE
Risk of damage due to electrostatic discharge
Electrostatic discharge from the human body may damage parts of the illumination unit
or the camera housing.
The illumination variants for lenses with a focal length of 12 mm or 16 mm do not
feature any plastic lenses in front of the LEDs in the round recesses.
■
Take the necessary ESD precautions when assembling the device.
■
Do not insert your fingers into the recesses.
■
Do not touch the open contacts of the electrical connection for the illumination
unit on the camera housing.
NOTE
Possible impairment of image quality
Dust and fingerprints on optical boundary surfaces can decrease the image quality and
decoding performance of the device.
b
Ensure a dust-free and dry environment when mounting components.
b
Do not touch the image sensor (CMOS) in the light inlet opening of the device with
your fingers.
b
Do not touch the glass lenses at either end of the lens unit with your fingers.
Auxiliary equipment required
•
SW 2 hexagon key (included with delivery)
•
SW 5 socket wrench, Recommendation: as a torque wrench for 65 Ncm
MOUNTING
5
8018071/1E1C/2021-12-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
25