11.3
Performance
Type
Lector63x Flex (V2D63xx-Mxxxxx)
Readable code struc‐
tures
1D, Stacked, 2D, DPM, OCR/OCV
1D code types (bar
code)
GS1-128 / EAN 128, UPC/GTIN/EAN, 2/5 Interleaved, Pharmacode, GS1 DataBar, Code 39, Code
128, Codabar, Code 32, Code 93
Postal codes
Postnet, Planet, USPS 4SCB, Australia Post, Dutch KIX Post, Royal Mail, Swedish Post
2D code types
Data Matrix ECC200, GS1 Data Matrix, MaxiCode, QR-Code
Stacked code types
PDF417
Code qualification
Based on ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 18004
OCR/OCV fonts
Trainable fonts
11.4
Interfaces
Type
Lector63x Flex (V2D63xx-Mxxxxx)
Serial RS-232/422
Function: host 1 (data output of the read result)
Data transmission rate: 300 Bd ... 115.2 kBd
Serial RS-232
Function: AUX 1 (Service)
1)
Data transmission rate: 57.6 kBd
USB 2.0
Function: AUX 3 (Service)
1)
CAN
Protocol: SICK CAN Sensor Network CSN (Master/Slave, Multiplexer/Server)
Function: host (data output of the read result)
Data transmission rate: 50 kBit/s ... 500 kBit/s
Bus length: maximum 30 m (depending on the data transmission rate)
Ethernet
Protocols:
•
TCP/IP
•
EtherNet/IP™
Functions
•
host 2 (data output of the read result)
•
AUX 2 (Service)
1)
•
FTP (image transfer)
Data transmission rate: 10/100/1,000 MBit/s
MAC address (device-specific), see type label
PROFIBUS
Function: host (RS-232, data output of the read result)
Type of fieldbus integration: optionally over external CDF600-21xx fieldbus module
3)
to bus
(RS-485)
Function blocks for various PLC manufacturers are available online at:
PROFINET (line topol‐
ogy)
Function: host (RS-232, data output of read result), PROFINET Single Port, PROFINET Dual Port
Type of fieldbus integration: PROFINET Single Port, PROFINET Dual Port optionally via external
CDF600-22xx fieldbus module
3)
to bus (Ethernet)
Function blocks for various PLC manufacturers are available online at:
Digital inputs
Type: 2 physical, switching (“Sensor 1”, “Sensor 2”)
Optional 2 additional external logical inputs (software-controlled) via the CMC600
3)
parameter
cloning module in the CDB650-204
3)
or CDM420-0006
3)
connection module
V
in
4)
= max. 32 V, I
in
5)
= max. 5 mA
Opto-decoupled, reverse polarity protected, adjustable debounce time
Configurable inputs
Encode input, external trigger
TECHNICAL DATA
11
8018071/1E1C/2021-12-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
67
Subject to change without notice