4
Name of the digital output
5
Auxiliary interface “AUX”
6
Male connector, D-Sub, 9-pin
7
SENSOR = Device
8
Female connector, M12, 17-pin, A-coded
9
Device to be connected
ß
The optional CMC600 parameter cloning module is required in the connection module in order to use the additional
external digital inputs and outputs of the device (highlighted in gray).
à
Supply voltage V
S
13.2.3
Connecting supply voltage for the device in CDB650-204
Device = Lector63x = V2D63xx-xxxxBx
Device
3
CDB650-204
V
S
V
S
2
1
2
1
5
Shield
1
U
IN
2
GND
U
IN
*
GND
S1
F
Shield
Cable
2
GND
.
.
.
.
.
.
.
.
.
ON
OFF
S1 : POWER
V
s
U
IN
*
POWER
GND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
V
S
-
U
IN
-
F
S 1
-
U
IN
*
5
4
1
Figure 20: Connecting supply voltage for the device in CDB650-204 connection module.
1
Supply voltage V
S
2
Connection cable 1:1 (male connector, M12, 17-pin, A-coded / female connector, M12,
17-pin, A-coded)
3
Device
4
Device: male connector, M12, 17-pin, A-coded
5
Connection module: female connector, M12, 17-pin, A-coded
Function of switch S1
Table 18: Switch S1: Power
Switch setting
Function
ON
Supply voltage U
IN
connected to CDB650-204 and device via fuse and
switch S1 as a supply voltage U
IN
*
Supply voltage U
IN
* can be additionally tapped at terminals 11 and 14.
OFF
CDB650-204 and device disconnected from supply voltage
Recommended setting for all connection work
13
ANNEX
72
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
8018071/1E1C/2021-12-16 | SICK
Subject to change without notice