COMMISSIONING
6
107
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
6.6.2
Configuring system functions for vehicle detection
6.6.2.1
Defining the position and rotation of the LMS Width and LMS Length
Define the exact positions of the sensor components used for vehicle detection.
The values entered must be based on the zero-point of the coordinate system.
Roughly aligning components
Provisionally align the sensor components in the graphical display of the live view.
1. Click on a component in the live display.
2. Click on the component again and keep the mouse button pressed. A grid appears to
serve as a guide.
3. Now move the component to the relevant plane.
The orientation of the grid will automatically adapt to the current perspective of the live
view. Rotate the measurement site in the live view to switch between displaying the grid
along the X-axis and the Z-axis, respectively.
Precisely adjusting components
Now define the exact positions of the sensor components.
Above all, pay attention to the positioning and alignment of the components in the
X-direction. The devices are finely positioned in the Y-direction when starting the
configuration via Floor Finding (for more information, see chapter
The exact angle positions must be specified for a TIC501.
Note
Note