COMMISSIONING
6
115
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
6.6.3
Configuring system functions for axle counting
6.6.3.1
Defining the position and rotation of the LMS Axle
Define the exact position and rotation of the LMS Axle. We recommend displaying the
measurement points for the 2D LiDAR sensor in question for this process.
Please note: TEMS Manager always shows the LMS Axle on a gantry. You can move and
rotate the 2D LiDAR sensor freely in any direction and thus define a mounting position
independently of its position on the gantry.
The
LMS
Axle
must be in the same Z-plane as the respective system function for vehicle
classification.
Roughly aligning components
First align the 2D LiDAR sensor in the graphical display of the live view.
1. Click on a component in the live display.
2. Click on the component again and keep the mouse button pressed. A grid appears to
serve as a guide.
3. Now move the component to the relevant plane.
The orientation of the grid will automatically adapt to the current perspective of the live
view. Rotate the measurement site in the live view to switch between displaying the grid
along the X-axis and the Z-axis, respectively.
Notes
Note