ANNEX
9
183
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
9
Annex
9.1
Technical data
9.1.1
TIC102 data sheet
TIC102 master
TIC102 slave
Features
System part
TIC102
(integrated
evaluation unit)
TIC102 Slave
(without evaluation unit;
must be connected to a
TIC102 Master)
Integrated application
Vehicle classification, traffic counting,
axle counting *
*
Another LMS511 SE is required for axle counting.
Scanner version
Two-scanner solution
Vehicle data
Vehicle class (various categorization systems with up
to 30 classes)
Direction of travel
Lane assignment
Confidence level for all vehicle data
Point clouds
Number of lanes covered
1
Recommended distance between
maximum vehicle height and sensor
Typ. 1.5 m
Calibration
Automatic
Laser class
1 eye-safe (IEC 60825-1 (2007-3))
Heating
Yes
Integrated computer unit
Traffic Controller TIC
–
Performance
Counting accuracy
> 99.8%
Classification accuracy
Typ. 98% (for TLS8+1 classes)
Interfaces
Data log
TEMS Info interface
(TCP/IP interface)
TEMS Manager (HTTP
configuration software)
–
NTP synchronization
Yes
–
Mechanics/electronics
Supply voltage
24 V DC (22.8 V DC ... 25.2 V DC)
Power consumption
130 W, with heating
51 W, without heating
120 W, with heating
41 W, without heating
Dimensions
355 mm x 482 mm x 373 mm
Weight
16.1 kg
15 kg
Mounting position
Above the lane
Installation height
6 m, 5 m ... 8 m
Enclosure rating
IP 66 (EN 60529)
Ambient data
Ambient operating temperature
–20 °C ... +50 °C *
* Protect the TIC102 from direct sunlight with a weather guard
to keep it from overheating.
Tab. 29: TIC102 data sheet