ELECTRICAL INSTALLATION
5
79
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
1. Connect the Ethernet cable on one of the two
ETH_INTERNAL
female connectors on
the TIC102 Master and fasten the plug connector.
2. Lead the cable to the next TIC102 Slave and screw the cable to the
ETH_INTERNAL
female connector.
Fig. 86: TIC102 electrical installation – Connecting the TIC102 sensors
3. Also connect the other TIC102 Slaves to the
ETH_INTERNAL
female connectors.
Ethernet cable
Pin
Wire color
Connection
1
Ethe
Ethernet interface
2
Ethe
Ethernet interface
3
Ethernet_TX–
Ethernet interface
4
Ethernet_RX–
Ethernet interface
Tab. 14: Electrical installation of the TIC102 – Ethernet cable pin assignment
5.3.3
Connect TIC102 Master to the customer interface
Connect the TIC102 Master to the company network. Use the Ethernet cable available as
an accessory. This has an M12 plug connector for connection to the TIC102 Master on
one end. The other end has an RJ45 male connector for connection to the company
network.
The TIC102 Master can be connected directly to the company network via a network
switch provided at the customer site.
▸
Connect the
ETH_HOST
connection of the TIC102 Master to the Ethernet connection of
the relevant client.
Fig. 87: Electrical installation of the TIC102 – Connection to the customer interface