9
ANNEX
184
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
9.1.2
TIC502 data sheet
TIC502 master
TIC502 slave
Features
System part
TIC502 Master
(with separate evaluation
unit)
TIC502 Slave
(without evaluation unit;
must be connected to a
TIC502 Master or Traffic
Controller TIC via an
Ethernet switch)
Integrated application
Vehicle classification, traffic counting,
speed detection, axle counting *
*
Another LMS511 SE is required for axle counting.
Scanner version
Two-scanner solution
Vehicle data
Vehicle class (various categorization systems with up
to 30 classes)
Direction of travel
Speed
Lane assignment
Confidence level for all vehicle data
Point clouds
Number of lanes covered
1
Recommended distance between
maximum vehicle height and sensor
Typ. 1.5 m
Calibration
Automatic
Laser class
1 eye-safe (IEC 60825-1 (2007-3))
Heating
Yes
Separate computer unit
Traffic Controller TIC
–
Performance
Counting accuracy
> 99.85%
Classification accuracy
Typ. 98% (for TLS8+1 classes)
Accuracy of speed measurement
± 3 km/h at < 100 km/h
*
± 3% at > 100 km/h
*
Only for vehicles with directional stability which pass under the
LMS Length
Interfaces
Data log
TEMS Info interface
(TCP/IP interface)
TEMS Manager (HTTP
configuration software)
–
NTP synchronization
Yes
–
Mechanics/electronics
Supply voltage
24 V DC (22.8 V DC ... 25.2 V DC) for the LMS511 2D
LiDAR sensor
24 V DC (12 V DC ... 36 V DC) for the Traffic Controller
Power consumption
120 W, with heating
54 W, without heating
110 W, with heating
44 W, without heating
Dimensions (L x W x H)
498 mm x 411 mm x 191 mm
(only mounting plate with pre-assembled LMS511)
Weight
12.8 kg
12 kg
Mounting position
Above the lane
Installation height
6 m, 5 m ... 8 m
Ambient data
Ambient operating temperature
–40 °C ... +60 °C *
* Protect the TIC502 from direct sunlight with a weather guard
to keep it from overheating.
Tab. 30: TIC502 data sheet