5
ELECTRICAL INSTALLATION
78
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
2. Run the cable to the power supply.
3. Connect the wires to the terminals of the voltage supply.
Fig. 85: Electrical installation of the TIC102 – Connection to the voltage supply (control cabinet)
▸
Connect the wires to the power supply in the control cabinet as follows:
Marking and color of the wires (free end)
7/8" x 5 male connector
Marking (wires)
Wire color
Description
Diagram
Pin
(1)
Black
Not assigned
1
(2)
Black
Earthing (–GND)
2
(3)
Black
Voltage (+24 V)
4
(4)
Black
Not assigned
5
(5)
Green-yellow
Protection earth
3
Tab. 13: Electrical installation of the TIC102 – Power cable pin assignment
For the voltage supply, use a cable with a suitable cross-section so that the voltage loss
between the connection point and the TIC102 is within the tolerance zone.
5.3.2
Connecting TIC102 units to one another via Ethernet
If you are working with several TIC102 units, you must create a TCP/IP connection
between the individual components in a series connection.
Use the Ethernet cables available as an accessory. They feature the required M12 plug
connector on both sides.
No separate network switch is required for this. It is integrated into the TIC102 housing.
Note